Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The CAD/CAM Compound Prosthesis: Digital Workflow for Fabricating Cement-Retained Zirconia Prosthesis Over Screw-Retained Milled Titanium Bars
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 39 , Issue 1
January/February 2019

Pages 39–47


The CAD/CAM Compound Prosthesis: Digital Workflow for Fabricating Cement-Retained Zirconia Prosthesis Over Screw-Retained Milled Titanium Bars

Meisam Faeghinejad, DDS, MSD/Periklis Proussaefs, DDS, MS/Abdulaziz AlHelal, BDS, MS/Jaime Lozada, DDS


PMID: 30543725
DOI: 10.11607/prd.3409

The computer-assisted design/computer-assisted manufactured compound prosthesis involves designing and milling a cement-retained prosthesis over milled titanium bars. In the presented clinical case report, a diagnostic wax pattern was made to assess esthetics, contours, and occlusion. A total of eight maxillary root-form implants were restored by following the combined prosthesis design concept. The mandibular arch was restored with a screw-retained implant-supported zirconia fixed prosthesis. A milled polymethyl methacrylate (PMMA) maxillary interim prosthesis was fabricated to intraorally confirm the diagnostic wax pattern. The interim PMMA prosthesis was then scanned, and three screw-retained titanium milled bars were designed that provided the substructure of the definitive restoration. A cement-retained milled zirconia prosthesis was then designed and fabricated. The zirconia prosthesis provided the superstructure of the definitive complete-arch restoration. After confirming esthetics, phonetics, occlusion, and accessibility for oral hygiene, the superstructure was cemented with temporary cement to enable retrievability.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help